Home >> Shop >> Gas detection >> Drager Ozone (10 – 300 ppm) detection tube
Drager Ozone (10 – 300 ppm) detection tube  [CH21001]
Drager Ozone (10 – 300 ppm)  detection tube
Click to zoom image
Drager Ozone (10 – 300 ppm)  detection tube
Bookmark and Share Bookmark and Share
OZONE short term detection tube. Range 10 to 300 ppm
£64.51 (ex VAT)
£64.51 (incl VAT) Status:  In Stock
discontinued
Order Code
CH21001
Rating

Write a review

Short Term tubes are used to measure concentration of specific contaminants instantaneously. Currently, about 160 short term Draeger tubes are available for determining and measuring more than 350 different gases, vapors and aerosols. (Please contact us if you cannot find what you are looking for)

The majority of the short term Draeger Tubes are scaled tubes, operating on a defined sample volume drawn through the tube by performing a specified number of pump strokes. The concentration of the contaminant is read directly from the calibrated scale by assessing the length of the discoloration.

Short term measurements can be made manually with the Accuro gas detector pump or automatically with the battery operated Accuro 2000. see Related products below for all pumps mentioned.

Selection

A tube should be selected to detect each suspected chemical. Simply locate the contaminant and select the tube according to the chemical hazard to be tested and the measuring range. Order the tube online or by phone,

Note: Measuring range information pertains to air monitoring only.

How The System Works

Simple 4 step operation:

  1. Select the appropriate Draeger Tube for chemical hazard and expected concentration.
  2. Open tube and insert in pump.
  3. Pull sample through tube.
  4. Read concentration directly from the colour band on the scale. 

If the designated air contaminant is present, it reacts with the chemical reagent in the tube, producing a colour change. The length or intensity of the colour band indicated contaminant levels - the longer or darker the stain, the higher the concentration. 

Caution: Interchanging Draeger Pumps and Tubes with other brands may cause erroneous results and should not be done. 

Application

  • Measuring concentration at a specific moment (e.g. concentration peaks)
  • Detecting leaks (e.g. in pipelines or gas installations)
  • Investigating confined space (e.g. canals, tunnels or tanks)
  • School and Plant Operators
  • Industrial Hygienists
  • HVAC Engineers
  • Building Maintenance Supervisors
  • Indoor air quality test Professionals
  • Insurance Claim Adjusters
  • Homeowners
  • Hospital Engineers
  • Law Enforcement
  • Hazmat
  • WMD
  • Waste Water Treatment
  • Refineries
  • Occupational Health and Safety Professionals





Drager Accuro Detector Tube Hand Pump Only
Drager accuro Hand-Held Pump with deluxe tube breaker and Allen wrench.
£360.05
Drager Accuro Deluxe Detector Tube Pump Kit
Drager Deluxe Detector Tube Pump Kit with accuro hand-held pump with automatic stroke counter, deluxe tube breaker, spare parts kit, tool kit, detector tube handbook, and carry case.
£765.02
Drager Tube Opener 7000, Scorer/Breaker
Drager Deluxe Tube Opener 7000, Scorer/Breaker. Scores and breaks the ends off glass tubes.
£51.54
Drager Carbon Dioxide Long Term Diffusion Tubes 250 to 6,000 ppm
Carbon Dioxide Long Term Diffusion Tubes from Draeger Safety.Standard Range250 to 6,000 ppm
£88.70